Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

dc.contributor.authorIto, T. M.
dc.contributor.authorAdamek, E. R.
dc.contributor.authorCallahan, N. B.
dc.contributor.authorChoi, J. H.
dc.contributor.authorClayton, S. M.
dc.contributor.authorCude-Woods, C.
dc.contributor.authorCurrie, S.
dc.contributor.authorDing, X.
dc.contributor.authorFellers, D. E.
dc.contributor.authorGeltenbort, P.
dc.contributor.authorLamoreaux, S. K.
dc.contributor.authorLiu, C. Y.
dc.contributor.authorMacDonald, S.
dc.contributor.authorMakela, M.
dc.contributor.authorMorris, C. L.
dc.contributor.authorPattie, R. W.
dc.contributor.authorRamsey, J. C.
dc.contributor.authorSalvat, D. J.
dc.contributor.authorSaunders, A.
dc.contributor.authorSharapov, E. I.
dc.contributor.authorSjue, S.
dc.contributor.authorSprow, A. P.
dc.contributor.authorTang, Z.
dc.contributor.authorWeaver, H. L.
dc.contributor.authorWei, W.
dc.contributor.authorYoung, A. R.
dc.date.accessioned2025-02-20T15:51:56Z
dc.date.available2025-02-20T15:51:56Z
dc.date.issued2018-01-29
dc.descriptionThis record is for a(n) offprint of an article published in Physical Review C on 2018-01-29; the version of record is available at https://doi.org/10.1103/physrevc.97.012501.
dc.description.abstractThe ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was 184(32) UCN / cm$^3$ , a fourfold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be 3 (7) UCN / cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of σ(d$_n$) = 3 × 10$^{−27}$ $e$ cm .
dc.description.versionoffprint
dc.identifier.citationIto, T. M., et al. "Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment." Physical Review C, vol. 97, no. 1, 2018-01-29, https://doi.org/10.1103/physrevc.97.012501.
dc.identifier.otherBRITE 3022
dc.identifier.urihttps://hdl.handle.net/2022/33246
dc.language.isoen
dc.relation.isversionofhttps://doi.org/10.1103/physrevc.97.012501
dc.relation.journalPhysical Review C
dc.titlePerformance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
3022_Performance-of-the-upgraded.pdf
Size:
1.21 MB
Format:
Adobe Portable Document Format
Can’t use the file because of accessibility barriers? Contact us