Exercise in personal protective equipment in a hot, humid environment does not affect risk propensity

Abstract

We tested the hypothesis that heat stress created by light exertion in encapsulating personal protective equipment (PPE) in a hot, humid environment increases risk propensity. Ten healthy subjects (29 ± 7 y) completed 2 trials presented in a counter-balanced manner. Subjects donned encapsulating PPE, and in one trial they wore a tube-lined shirt underneath that was perfused with 5°C water. Subjects completed 2 15 min bouts of walking exercise on a treadmill at ˜50% maximal heart rate in a 32°C, 81% RH environment. Subjects completed the Balloon Analog Risk Task (BART), an objective measure of risk-taking, before, between the 2 exercise bouts, and following the final exercise bout. Personal cooling lowered (P < 0.01) mean skin temperature by 8.0 ± 1.6°C. Intestinal temperature rose (P < 0.01) in both trials, but was lower (P < 0.01) at the end of exercise in the cooling trial (38.0 ± 0.3°C vs. 37.6 ± 0.3°C). BART derived indices of risk propensity were not affected by trial or time (trial × time interaction: P ≥ 0.33). These data indicate that 60 min of exposure to mild heat stress created by light exertion in encapsulating PPE does not affect risk-taking behavior.

Table of Contents

Description

Keywords

dexterity, heat stress, personal cooling, risk-taking

Citation

Schlader ZJ, Temple JL, Hostler D. Exercise in personal protective equipment in a hot, humid environment does not affect risk propensity. Temperature 3: 262-270, 2016.

Journal

Relation

Rights

This work is under a CC-BY-NC license. You are free to copy and redistribute the material in any format, as well as remix, transform, and build upon the material as long as you give appropriate credit to the original creator, provide a link to the license, and indicate any changes made. You may not use this work for commercial purpose.